INSTALLATION INSTRUCTIONS
95-7511-4
® U.S. Registered Trademark
Copyright © 2002 Honeywell International Inc.
All Rights Reserved
Q7760A
SLTA 10 Serial LonTalk
®
Adapter
BEFORE INSTALLATION
The SLTA-10 (Serial Interface or Serial LonTalk
®
Adapter)
provides communication between the L
ONWORKS® Bus and
either a PC serial port or approved modem using the SLTA-10
EIA-232 port. The SLTA-10 Q7760A2001 operates with the
Light Commercial Building Solution and the Excel 10 series
2000 family of controllers. It interfaces with L
ONSPEC™,
L
ONSTATION™, LONSTAT™, and E-Vision software. The
SLTA-10 Q7752A1011 operates with the Excel 10 VAV1 series
1000 controller and interfaces with LiveCare software.
There are two separate firmware images in the SLTA-10. The
two separate images have different link layer protocols,
network drivers, buffer capacity, and functionality. The two
modes of operation are SLTA-10 NSI mode and SLTA-10 MIP
mode. An externally accessible DIP switch at power-up
controls the mode of operation.
In SLTA-10 MIP mode, the SLTA-10 is a replacement for the
SLTA/2 Serial LonTalk
®
Adapter, with an improved form factor.
The network connector on the SLTA-10 is the orange
removable screw terminal instead of the RJ-45 used on the
SLTA/2. The SLTA-10 input power options include 9 to 30 Vac
or Vdc, or a 9 Vdc power supply. The SLTA-10 configuration
DIP switches are accessible externally. The SLTA-10
enclosure has been improved to allow wall mounting without
requiring a bracket.
CONFIGURING THE SLTA-10
HARDWARE
The SLTA-10 can be configured for direct communications
with a PC serial port, or remote communications with a
modem. Configure the SLTA-10 with its eight configuration
switches on the adapters switch block (S1). The SLTA-10
firmware reads these switches to configure or enable features.
Changes to the switch configurations do not occur until power
is cycled on the SLTA-10. The switches are read immediately
after a power reset. The configurations for Direct and Remote
are different, see their separate sections.
Direct Connections LONSPEC™ LONSTATION
L
ONSTAT™ E-Vision and LiveCare
1. Set the switches for direct connection to an PC serial
port as shown in Fig. 1.
Fig. 1. Dip Switch Settings.
2. Cycle power to enable the new configuration on the
SLTA-10.
Drivers
NodeTalk: LONSPEC™, LONSTATION™, and LONSTAT™ use
the NodeTalk driver to manage SLTA-10 communications.
The NodeTalk driver is built into the software.
LDVSLTA.SYS: E-Vision and LiveCare use the
LDVSLTA.SYS driver to manage SLTA-10 communication.
This driver has not changed, and is included with both
E-Vision and LiveCare. The Config.sys must be modified to
call this driver. Add a line to Config.sys similar to
Device=C:\E-Vision\ldvslta.sys /D1 /P1 /A.
NOTE: /Pn (n can be 1 or 2) determines the COM port.
/A means autobaud.
Remote Connections
Remote communication configurations vary greatly between
the Light Commercial Building Solution and the Excel 10
controllers. Both systems require an approved modem
connected to the EIA-232 port on the SLTA-10 with an SLTA
modem cable (Honeywell part number 32002517-001; DB-9
male to DB-25 male non-standard). The PC must have the
same modem. See Fig. 2.
NOTE: Do not select AutoBaud for remote connections.
Fig. 2. Remote connection.
M1722
6
1
2
3
4
56 78
ON/UP
OFF/DOW
N
M17231
A
MODEM
DB25
MALE
DB9
MALE
SLTA-10
SLTA-10 NULL
MODEM CABLE
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Adapter

INSTALLATION INSTRUCTIONS95-7511-4® U.S. Registered TrademarkCopyright © 2002 Honeywell International Inc.All Rights Reserved Q7760ASLTA 10 Serial Lon

Page 2 - E-Vision and LiveCare

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER95-7511—4 2Approved Modem: US Robotics 56K external V.90.Modem Dip Switch Setting:3, 4, and 8 down. All other sw

Page 3 - 3 95-7511—4

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER3 95-7511—4Fig. 5. Link Description Screen.5. Enter phone number of remote site (see Fig. 6).6. Select modem fro

Page 4 - FRONT VIEW BACK VIEW

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER95-7511—4 4Fig. 8. SLTALink Manager Screen.14. Start E-Vision.15. Open Project.16. Select View.17. Click On-line

Page 5 - CABLING AND CONNECTIONS

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER5 95-7511—4Table 1. SLTA-10 Interface.CABLING AND CONNECTIONSEIA-232 devices are configured as either Data Circu

Page 6 - PC (DTE)

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER95-7511—4 61. Plug the male end of the DB-9 connector into the SLTA-10.2. Plug the female end of the DB-9 into t

Page 7 - ORDERING INFORMATION

Q7760A SLTA 10 SERIAL LONTALK® ADAPTER7 95-7511—4Table 5. SLTA-10 Power Supply Requirements.When power is connected, the yellow service LED flashes br

Page 8 - Fax (49-7031) 637-493

Automation and Control Solutions ACS Control ProductsHoneywell International Inc. Honeywell Limited-Honeywell Limitée Honeywell AG1985 Douglas Drive N