NodeBuilder Errors Guide 7-5
PMK# Description
132
Cannot read the hardware platforms database <file>.
[PMK#132]
Make sure the platform’s database file <file> exists. The default
location for this database file is
\LonWorks\NodeBuilder\Templates\Hardware\nbplatforms.xml
133 Library <lib> is required but cannot be found [PMK#133]
The Project Make Facility has aborted the build process because a
library <lib> is required, but cannot be found.
4001
An empty program ID has been specified. It is recommended
to change the program ID, using the device template editor
[PMK#4001]
An empty program ID, i.e. a program ID without a value, has been
specified. It is recommended to change the program ID, using the
device template editor. This might result in a compilation failure.
This message should not occur when using a machine-generated
device template file.
4002
The configured program ID results in an unstable build
status, and may not suitable for automatic management. It
is recommended to reconsider the specified program ID, or to
disable program ID management. This might lead to a
failure in the remaining build process [PMK#4002]
This message indicates that program ID management causes an
unstable build status. This loop condition has been detected after
three fix-up compilation attempts, and the fix-up attempts have
been aborted to prevent an endless loop condition. A fix-up
compilation might occur as a result of automatic program ID
management, where the PID manager detects an interface change
after the initial compilation, where the interface change impacts
the compiler's DRF lookup. Thus, a re-compilation is attempted
with the new program ID, and in this particular case, the problem
persists. This effect might be caused by the combination of
automatic program ID management and a DRF scope value 6. This
combination is not recommended for use in NodeBuilder 3, because
program ID management modifies the model field, and the scope 6
resource file expects the model field not to change.
4003
Can't write file <make dependency file>. This might cause
the build status calculator to malfunction, but does not
impact the build results (system error code <code>)
[PMK#4003]
Failure to write a .nkdep dependency file. Insufficient write-
permission, or a write-protected media could cause this effect. This
failure does not harm the build itself, but causes the build status
calculator not being able to determine the build status correctly.
Solution: make .nkdep file writable, or disable automatic program
ID management.