i.LON SmartServer 2.0 Programmer’s Reference
2-1
2 SOAP Messages and the SmartServer WSDL File
This chapter contains general information about the SOAP/XML interface you will need to know
before using the SOAP functions described in this manual. It includes the following major topics:
SmartServer Naming Structure. The section describes how the SmartServer’s data configuration
is organized.
SmartServer WSDL File. This section describes the version 4.0 WSDL file, which defines the
SOAP/XML interface. When writing applications to use the SOAP interface, some tools can
import this file and automatically build a class structure for sending and receiving each message.
Security. This section describes the security provided by the SmartServer for SOAP applications.
SOAP Request/Response Structure. This section demonstrates the structure of the SOAP request
and response messages used by Version 4.0.
SOAP Message Formats. This section describes the formats that must be used for all SOAP
messages that are sent to and from the SmartServer. A SOAP message is sent to the SmartServer
each time you invoke any of the functions described in this document.
Data Point References. The section describes the SmartServer’s new method for referencing data
points on the SmartServer’s embedded applications.
UCPTCurrentConfig. This section describes the new <UCPTcurrentConfig> element included in
List response messages. This element indicates the namespace version of the client that last set the
configuration of an item.
Fault Structure. This section describes the new <Fault> structure, which combines the faultcode
and faultstring elements and enables a client to check only for the existence of a fault structure
instead of having to check for both elements.
LonString Type. This section describes the E_LonString type that is used for enumerations or
element values that have format descriptions that depend on references to other data point formats.
SOAP Examples. This section includes SOAP examples that demonstrate how to use the Version
4.0 SOAP interface to get the configuration of data point, write a value to a data point in a Web
connection, and read the data in a data logger.
2.1
SmartServer Naming Structure
The naming convention used for the SmartServer’s configuration and data items follows the
L
ONWORKS network hierarchy (network/channel/device/functional block/data point).
When the SmartServer accesses a device, that device is attached to a given channel in a network. In
the same manner, a data point exists on a functional block that is part of the device. This structure is
reflected by the network/channel/device/functional block/data point naming scheme.
Assuming that there is a channel named “myChannel” on a network called “myNetwork, the name of a
device accessed through “myChannel” must begin with “myChannel”. For example, the default
<UCPTname> property of the internal automated system device on the SmartServer (i.LON App) is
Net/LON/i.LON App. This means that the SmartServer is located on a channel named LON on a
network named Net. Further consider that i.LON App has a Digital Input 1 functional block that
contains an nvoClsValue_1 data point. By default, the <UCPTname> property of the nvoClsValue_1
data point is Net/LON/iLON App/Digital Input 1/nvoClsValue_1. Note that a <UCPTname>
property has to have at least the size of one char and must be unique in the
network/channel/device/functional block/data point collection.