i.LON SmartServer 2.0 Programmer’s Reference
21-44
'get the device template to show FBs and DPs in Web UI
my_LON_Device2.Command(2) = New iLON_SmartServer.LON_Device_CfgCommand()
my_LON_Device2.Command(2).UCPTcommand = New iLON_SmartServer.LON_Device_eCommand()
my_LON_Device2.Command(2).UCPTcommand = iLON_SmartServer.LON_Device_eCommand.GetTemplate
my_LON_Device2.Command(2).UCPTstatus = New iLON_SmartServer.E_LonString()
my_LON_Device2.Command(2).UCPTstatus.LonFormat = "UCPTstatus"
my_LON_Device2.Command(2).UCPTstatus.Value = "STATUS_REQUEST"
'Call the Set() function
Dim Device_Return_ItemColl As iLON_SmartServer.Item_Coll = SmartServer._iLON.Set(ItemCfgColl)
Device_Return_ItemColl.xSelect = "//Item[@xsi:type=""LON_Device_Cfg""]"
If Device_Return_ItemColl.UCPTfaultCount > 0 Then
' print out error and exit
Console.Out.WriteLine("An error occurred:")
For j As Integer = 0 To Device_Return_ItemColl.Item.Length - 1
If Device_Return_ItemColl.Item(j).fault IsNot Nothing Then
Console.Out.WriteLine(("Item: " & Device_Return_ItemColl.Item(j).UCPTname &
", fault code: " & Device_Return_ItemColl.Item(j).fault.faultcode.Value &
", fault string: ") & Device_Return_ItemColl.Item(j).fault.faultstring)
End If
Next
Else
ItemCfgColl = SmartServer._iLON.Get(Device_Return_ItemColl)
For j As Integer = 0 To ItemCfgColl.Item.Length - 1
Dim newDevice As iLON_SmartServer.LON_Device_Cfg =
DirectCast(ItemCfgColl.Item(j), iLON_SmartServer.LON_Device_Cfg)
Console.WriteLine((("New Device Created = " & newDevice.UCPTname & ". Status = ") +
newDevice.UCPTcommissionStatus.Value & " and ") +
newDevice.UCPTapplicationStatus.Value & "." & vbCr)
Next
End If
Console.ReadLine()
Finally
SmartServer.CloseBindingToSmartServer()
End Try
End Sub
End Module
21.2.5
Commissioning External Devices in Visual Basic.NET
This VB console example reads the <UCPTitemStatus> of external LonWorks devices (obtained using
an xSelect), commissions any unconfigured devices, and reports the status of the network management
commands. Note that this example does not include code for checking that all the network
management commands have been completed before terminating.
You can execute this code after you have referenced and inherited from the SmartServer WSDL as
described in
section 20.1, and instantiated and initialized the Web service client as described in section
20.2.3.
For more information on the network management commands issued in this example, see
section
14.3.3.1,
Issuing Network Management Commands.
Module CommDeviceModule
Sub Main()
'See Section 20.2.3 for more information on iLON_SoapCalls class
Dim SmartServer As iLON_SoapCalls = New iLON_SoapCalls
SmartServer.BindClientToSmartServer()
Try